{"id":2228,"date":"2022-10-11T06:53:40","date_gmt":"2022-10-11T06:53:40","guid":{"rendered":"https:\/\/www.lindenphotonics.com\/lpicables\/?page_id=2228"},"modified":"2022-10-13T17:04:15","modified_gmt":"2022-10-13T17:04:15","slug":"fiber-to-antenna-ftta-solutions-for-radio-based-stations","status":"publish","type":"page","link":"https:\/\/www.lindenphotonics.com\/lpicables\/fiber-to-antenna-ftta-solutions-for-radio-based-stations","title":{"rendered":"FIBER TO ANTENNA, FTTA SOLUTIONS FOR RADIO BASED STATIONS"},"content":{"rendered":"<p>[vc_row row_content_width=&#8221;grid&#8221; row_background_shadow=&#8221;no&#8221; el_class=&#8221;one&#8221; css=&#8221;.vc_custom_1664725122502{margin-right: -55px !important;margin-left: -55px !important;}&#8221;][vc_column el_class=&#8221;two&#8221;][vc_column_text]<\/p>\n<h2 class=\"cents\">OUTDOOR CABLES<\/h2>\n<h3 class=\"cent\">FIBER TO ANTENNA, FTTA SOLUTIONS FOR RADIO BASED STATIONS<\/h3>\n<h2 class=\"cents\">Tactical Optical Fiber Cables<\/h2>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row row_background_shadow=&#8221;no&#8221;][vc_column][vc_column_text][\/vc_column_text][vc_column_text]<\/p>\n<div class=\"blog-carousel-text-container\">\n<h3 class=\"bg_col\">Application<\/h3>\n<ul>\n<li>For connection of radio based stations<\/li>\n<\/ul>\n<\/div>\n<p>[\/vc_column_text][vc_single_image image=&#8221;2229&#8243; img_size=&#8221;full&#8221;][\/vc_column][\/vc_row][vc_row row_background_shadow=&#8221;no&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;Typical Cross section of 2 Fiber&#8221;][vc_single_image image=&#8221;2283&#8243; img_size=&#8221;full&#8221;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;Cable Construction Details&#8221;][vc_column_text]<\/p>\n<ul>\n<li>Enhance low water peak single mode fibers in full compliance with ITU-T-G.652.D (also available with G657 SM Fiber and OM1 \/ OM2 \/ OM3 &amp; OM4 MM Fiber)<\/li>\n<li>Tight coated fiber with Ny-12\/LSZH<\/li>\n<li>Aramid Yarn over tight coated fiber<\/li>\n<li>LSZH Sheath over Aramid yarn<\/li>\n<li>Polyester tape wrapping<\/li>\n<li>Corrugated Steel tape armoring<\/li>\n<li>Outer Sheath of UV resistant PE, Black<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row row_background_shadow=&#8221;no&#8221; css=&#8221;.vc_custom_1664615185211{margin-bottom: 20px !important;}&#8221;][vc_column][vc_custom_heading text=&#8221;Technical Characteristics&#8221; css=&#8221;.vc_custom_1664615305722{margin-bottom: 10px !important;}&#8221;][vc_column_text]<\/p>\n<div class=\"table-responsive\">\n<table class=\"table table-bordered table_head\">\n<thead>\n<tr style=\"background-color: #4d3d87; color: #fbf4f4; font-weight: bold;\">\n<td style=\"border-bottom: none;\" valign=\"top\" width=\"13%\">FIBER COUNT<\/td>\n<td style=\"border-bottom: none;\" valign=\"top\" width=\"12%\">DIAMETER (mm) Nominal<\/td>\n<td style=\"border-bottom: none;\" valign=\"top\" width=\"12%\">WEIGHT (Kg.\/Km) Nominal<\/td>\n<td colspan=\"2\" valign=\"top\">TENSILE STRENGTH (N)<\/td>\n<td colspan=\"2\" valign=\"top\">BENDING RADIUS (mm)<\/td>\n<td colspan=\"2\" valign=\"top\">TEMPERATURE RANGE<br \/>\n(IEC 60794-1-2-F1)<\/td>\n<\/tr>\n<tr style=\"background-color: #4d3d87; color: #fbf4f4; font-weight: bold;\">\n<td style=\"text-align: center; border-top: none;\" valign=\"top\"><\/td>\n<td style=\"text-align: center; border-top: none;\" valign=\"top\"><\/td>\n<td style=\"text-align: center; border-top: none;\" valign=\"top\"><\/td>\n<td style=\"text-align: center; border-top: none;\" valign=\"top\" width=\"11%\">Installation<\/td>\n<td style=\"text-align: center; border-top: none;\" valign=\"top\" width=\"10%\">Operating<\/td>\n<td style=\"text-align: center; border-top: none;\" valign=\"top\" width=\"9%\">Temporary<\/td>\n<td style=\"text-align: center; border-top: none;\" valign=\"top\" width=\"10%\">Permanent<\/td>\n<td style=\"text-align: center; border-top: none;\" valign=\"top\" width=\"11%\">Installation<\/td>\n<td valign=\"top\" width=\"12%\">Operating<\/td>\n<\/tr>\n<tr style=\"background-color: #d9d4e8; color: #0a0a0a;\">\n<td style=\"text-align: center; border-color: #F8F3F3;\">2F<\/td>\n<td style=\"text-align: center; border-color: #F8F3F3;\">8.5<\/td>\n<td style=\"text-align: center; border-color: #F8F3F3;\">70<\/td>\n<td style=\"text-align: center; border-color: #F8F3F3;\">350<\/td>\n<td style=\"text-align: center; border-color: #F8F3F3;\">300<\/td>\n<td style=\"text-align: center; border-color: #F8F3F3;\">15D<\/td>\n<td style=\"text-align: center; border-color: #F8F3F3;\">20D<\/td>\n<td style=\"text-align: center; border-color: #F8F3F3;\">-20\u00b0 to +50\u00b0 C<\/td>\n<td style=\"text-align: center; border-color: #F8F3F3;\">-40\u00b0 to +70\u00b0 C<\/td>\n<\/tr>\n<\/thead>\n<\/table>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row row_background_shadow=&#8221;no&#8221; css=&#8221;.vc_custom_1664615262709{margin-bottom: 20px !important;}&#8221;][vc_column][vc_column_text]<\/p>\n<div class=\"m-bot-40\">\n<h4>Color Coding &#8211; Fiber<\/h4>\n<ul>\n<li class=\"button small blue\">Blue<\/li>\n<li class=\"button small orange\">Orange<\/li>\n<li class=\"button small green\">Green<\/li>\n<li class=\"button small brown\">Brown<\/li>\n<li class=\"button small Grey\">Grey<\/li>\n<li class=\"button small white\">White<\/li>\n<li class=\"button small red\">Red<\/li>\n<li class=\"button small black\">Black<\/li>\n<li class=\"button small yellow\">Yellow<\/li>\n<li class=\"button small violet\">Violet<\/li>\n<li class=\"button small pink\">Pink<\/li>\n<li class=\"button small aqua\">Aqua<\/li>\n<\/ul>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row row_background_shadow=&#8221;no&#8221; css=&#8221;.vc_custom_1664615280574{margin-bottom: 50px !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;Special Features&#8221;][vc_column_text]<\/p>\n<ul>\n<li>Fiber-fed remote radios (RRs) offer significant power savings<\/li>\n<li>Reduces wind and weight load on towers; avoid costly tower upgrades.<\/li>\n<li>Reduces installation cost through fewer cables sheaths (70% less) compared to coax.<\/li>\n<li>Reduces installation time through fewer cable sheaths.<\/li>\n<li>Fast and easy connection and upgrade via tower-top terminal.<\/li>\n<li>Pre-provision for future equipment additions (spare ports).<\/li>\n<li>Ruggedized cable with corrugated steel tape armored providing termite resistance, protection against rodents, birds, squirrels &amp; monkey bite.<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_custom_heading text=&#8221;Drum Length&#8221;][vc_column_text]<\/p>\n<div class=\"container\">\n<div class=\"row m-bot-40\">\n<div class=\"col-md-6 wow zoomIn animated\">\n<div class=\"row\">\n<div class=\"col-md-12\">\n<ul>\n<li>1000\/2000 meters \u00b1 5%<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"footer-offset\" class=\"m-top-80\">\n<footer>\n<div class=\"footer-grey-bg title-lines-container\">\n<div class=\"container\">\n<div class=\"row\">\n<div class=\"col-md-4 wow fadeInLeft animated\" data-wow-duration=\"1s\">\n<div class=\"logo-container\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/footer>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;Mechanical Characteristics&#8221;][vc_column_text]<\/p>\n<table class=\"fonts_small\" width=\"99%\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\" width=\"56%\">Repeated Bending (IEC 60794-1-2-E6<\/td>\n<td align=\"left\" valign=\"top\" width=\"44%\">30 Cycle, 20 X D, 5 Kg Load, D = Cable D<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Torsion Resistance (IEC 60794-1-2-E7)<\/td>\n<td align=\"left\" valign=\"top\">10 Cycle (\u00b1 180\u00b0) 5 Kg Weight, L= 2 Mtr<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Crush Resistance (IEC 60794-1-2-E3)<\/td>\n<td align=\"left\" valign=\"top\">2000 N (100 X 100 mm) for 600 sec<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Impact Resistance (IEC 60794-1-2-E4)<\/td>\n<td align=\"left\" valign=\"top\">Height 500 mm, Weight = 5 Kg, 3 Nos at different points<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Kink Resistance (IEC 60794-1-2-E10)<\/td>\n<td align=\"left\" valign=\"top\">20 x D, D = Cable D<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row row_content_width=&#8221;grid&#8221; row_background_shadow=&#8221;no&#8221; el_class=&#8221;one&#8221; css=&#8221;.vc_custom_1664725122502{margin-right: -55px !important;margin-left: -55px !important;}&#8221;][vc_column el_class=&#8221;two&#8221;][vc_column_text] OUTDOOR CABLES FIBER TO ANTENNA, FTTA SOLUTIONS FOR RADIO BASED STATIONS Tactical Optical Fiber Cables [\/vc_column_text][\/vc_column][\/vc_row][vc_row row_background_shadow=&#8221;no&#8221;][vc_column][vc_column_text][\/vc_column_text][vc_column_text] Application For connection of radio based stations [\/vc_column_text][vc_single_image image=&#8221;2229&#8243; img_size=&#8221;full&#8221;][\/vc_column][\/vc_row][vc_row row_background_shadow=&#8221;no&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;Typical [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"full-width.php","meta":[],"_links":{"self":[{"href":"https:\/\/www.lindenphotonics.com\/lpicables\/wp-json\/wp\/v2\/pages\/2228"}],"collection":[{"href":"https:\/\/www.lindenphotonics.com\/lpicables\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.lindenphotonics.com\/lpicables\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.lindenphotonics.com\/lpicables\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lindenphotonics.com\/lpicables\/wp-json\/wp\/v2\/comments?post=2228"}],"version-history":[{"count":7,"href":"https:\/\/www.lindenphotonics.com\/lpicables\/wp-json\/wp\/v2\/pages\/2228\/revisions"}],"predecessor-version":[{"id":2284,"href":"https:\/\/www.lindenphotonics.com\/lpicables\/wp-json\/wp\/v2\/pages\/2228\/revisions\/2284"}],"wp:attachment":[{"href":"https:\/\/www.lindenphotonics.com\/lpicables\/wp-json\/wp\/v2\/media?parent=2228"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}